  • Accuracy

    Rod probe :+/- 2 mm (0.08 in)
    Rope probe <= 15 m (49 ft): +/- 2 mm (0.08 in)
    Rope probe > 15 m (49 ft): +/- 10 mm (0.39 in)
    Coaxial probe: +/- 2 mm (0.08 in)

  • Process temperature

    -50...+200 °C
    (-58...+392 °F)

  • Process pressure / max. overpressure limit

    Vacuum...40 bar
    (Vacuum...580 psi)

  • Max. measurement distance

    Rod: 10 m (33 ft) Min DK>1.6
    Rope: 25 m...30 m (82ft...98 ft) Min DK>1.6;
    30m...45 m (98ft...148 ft) Min DK>1,9
    Coaxial probe: 6 m (20 ft) Min DK>1.4

  • Main wetted parts

    Rod probe:
    316L, Alloy C, Ceramic
    Rope probe:
    316, 316L, Alloy C, Ceramic
    Coaxial probe:
    316L, Alloy C, Ceramic, PFA

Benefits

  • Increased productivity thanks to process monitoring, verification, and diagnostics in the running process with Heartbeat Technology
  • Safety by design: Device development according to IEC 61508 for SIL 2 and SIL 3 applications (e.g. in homogeneous redundancy)
  • Reduction of systematic errors through guided SIL-locking, verification and proof testing
  • Easy handling through intuitive operation and wizards, for commissioning and verifications

Version with rod, rope or coax probe.
  • Process connections: Thread or flange
  • Temperature: -50 to +200°C (-58 to +392°F)
  • Pressure: -1 to +40bar (-14.5 to +580psi)
  • Maximum measuring range: Rod 4m (13t), rope 10m (33ft), coax 6m (20ft)
  • Accuracy: Rod ±2mm (0.08")
  • International explosion protection certificates, overfill prevention WHG, SIL, marine approval