JK-C8001涡街流量计

2024-06-11

Specs at a glance
Max. measurement error


Volume flow (liquid): ±0.75 %Volume flow (optional): ±0.65 %
Volume flow (steam, gas): ±1.00 %
Mass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature/pressure compensated)
Mass flow (superheated steam, gas): ±1.5 (temperature/pressure compensated); ±1.7% (temperature compensated + external pressure compensation)
Mass flow (liquid): ±0.85%

Measuring range

Liquid: 0.076 to 2100 m³/h (0.045 to 1300 ft³/min)
depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
Steam, gas: 0.39 to 28000 m³/h (0.23 to 17000 ft³/min)
depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)
 

Medium temperature range

Standard: –40 to +260 °C (–40 to +500 °F)
High/low temperature (option): –200 to +400 °C (–328 to +752 °F)

Max. process pressure

PN 100, Class 600, 20K

Wetted materials

Measuring tube: 1.4408 (CF3M); CX2MW similar to Alloy C22, 2.4602DSC sensor: 1.4404 (316/316L); UNS N06022 similar to Alloy C22, 2.4602
Process connection: 1.4404/F316/F316L); 2.4602
Device properties

✓Wet steam capabilities for DN 25 to 300 (1 to 12")
✓Flexible positioning of pressure cell
✓Industrial siphon design for pressure measurement
✓Display module with data transfer function
✓Robust dual-compartment housing
✓Plant safety: worldwide approvals (SIL, Haz. area)